ZONELINE BUYING TIPS
ACCESSORY GUIDE FOR YOUR GE ZONELINE® PTAC
ACCESSORY GUIDE FOR YOUR GE ZONLINE PTAC
Zoneline packaged terminal air conditioner units are designed with universal components and offer great installation flexibility, whether in new construction, renovation or for replacement of old PTAC units.
ESSENTIAL ACCESSORIES
GE Zonelines require a set of essential accessories for proper operation. Once you have selected your type of unit (resistance heat or heat pump) and the size of unit needed, next you’ll need to consider the following:
- WALL SLEEVE / CASE
- EXTERIOR GRILLE
- POWER CONNECTIONS
For new properties, be sure to get a matching wall case with your GE Zoneline. For replacements, GE Zoneline fits in the standard 42 in × 16 in sleeve dimensions.
HEAVY GAUGE STEEL WALL CASE
RAB71B
- Heavy gauge galvanized steel, with insulation
- 42 in (A) × 13 3/4 in (B) × 16 in (C)
- Also available in 16 in, 24 in, 28 in and 31 in depths
WALL OPENING DIMENSIONS
- Add 1/4 in to A and C dimensions for all cutout size
- 16 1/4 in min (height) × 42 1/4 in min (width)
FIBERGLASS WALL CASE
RAB77B
- Molded SMC fiberglass-reinforced polyester compound
- 42 in (A) × 13 7/8 in (B) × 16 1/4 in (C)
WALL OPENING DIMENSIONS
- Add 1/4 in to A and C dimensions for all cutout size
- 16 1/2 in min (height) × 42 3/8 in min (width)
We offer three styles of exterior grilles to fit your building façade. The exterior air flow requirements have changed over the years. If reusing an existing grille, make sure that the air flow pattern is compatible with the new chassis. This may include removing existing air deflectors off the grille and installing the RAK40 air deflectors on the chassis.
ARCHITECTURAL GRILLE
RAG67 – Aluminum
COLOR MOLDED GRILLES
RAG61 – Beige
RAG62 – Maple
RAG63 – Dark Brown
STAMPED GRILLE
RAG60 – Aluminum
Power connection kits are required on all GE Zoneline chassis. The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring.
230/208-VOLT UNITS
These units may be plugged into a receptacle using a line power cord kit or hard-wired. If the unit is to be permanently connected, a permanent connection kit would be used. Some installations utilize sub-bases for support of the unit and to hide the electrical connection.
POWER CORD KITS
RAK315P (15 AMP) – NEMA6-15R
RAK320P (20 AMP) – NEMA6-20R
RAK330P (30 AMP) – NEMA6-30R
DIRECT CONNECT KITS
RAK315D (15 AMP)
RAK320D (20 AMP)
RAK330D (30 AMP)
SUB-BASES
230/208-volt sub-bases include the appropriate short power cord to connect to the receptacle inside the sub-base. A junction box kit is required to complete the direct connect installation.
RAK204D15C (15 Amp)
RAK204D20C (20 Amp)
RAK204D30C (30 Amp)
265-VOLT UNITS
265-volt units are provided with a junction box and require direct connection. 265-volt cord set units must be installed in compliance with National Electrical Code®.
POWER CORD KITS
To be used with a sub-base.
RAK515P (15 AMP) – NEMA7-15R
RAK520P (20 AMP) – NEMA7-20R
RAK530P (30 AMP) – NEMA7-30R
DIRECT CONNECT KITS
To be used with a sub-base or connection to building wiring. Direct connect kits include a power cord.
RAK515D (15 Amp)
RAK520D (20 Amp)
RAK530D (30 Amp)
SUB-BASES
Sub-bases do not include a power cord and junction box. Order a sub-base and the appropriate power cord or direct connect kit separately.
RAK204E15 (15 AMP)
RAK204E20 (20 AMP)
RAK204E30 (30 AMP)
OTHER ACCESSORIES
- DUCTED APPLICATIONS
- REMOTE THERMOSTAT
The 4500 and 6500 series can be used to heat or cool more than one room. A special adapter mounts on the wall case and a transition piece directs the air from the unit into added ductwork that distributes the air to the main room and the attached room.
DUCT ADAPTER
RAK6053
DUCT EXTENSION
RAK601B
DUCT EXTENSION
RAK602B
All Zoneline units are compatible with GE Appliances wall-mounted remote thermostats. We offer both digital and programmable wired thermostats.
4500 ELECTRIC RESISTANCE HEAT SERIES
-
COOLING WITH ELECTRIC HEAT DIGITAL THERMOSTAT
RAK164D2 -
COOLING WITH ELECTRIC HEAT PROGRAMMABLE THERMOSTAT
RAK164P2 -
DIGITAL TWO FAN SPEED THERMOSTAT FOR ELECTRIC RESISTANCE
RAK164F2
6500 HEAT PUMP SERIES
-
HEAT PUMP DIGITAL THERMOSTAT
RAK148D2 -
HEAT PUMP PROGRAMMABLE THERMOSTAT
RAK148P2 -
DIGITAL TWO FAN SPEED THERMOSTAT FOR HEAT PUMP
RAK148F2
ZONELINE BUYING TIPS
ACCESSORY GUIDE FOR YOUR GE ZONELINE VERTICAL AIR CONDITIONER
ACCESSORY GUIDE FOR YOUR GE ZONELINE VERTICAL AIR CONDITIONER
The GE Zoneline Vertical Air Conditioner is approximately 24 in × 24 in and has a top air discharge that is ducted into a single room or multiple rooms. Because the new Zoneline Vertical is installed in a closet, it provides a more home-like appearance to the room as well as quieter operation.
ESSENTIAL ACCESSORIES
GE Zonelines require a set of essential accessories for proper operation. Once you have selected your type of unit (resistance heat or heat pump) and the size of unit needed, next you’ll need to consider the following:
- WALL PLENUM
- GRILLE
- POWER CONNECTIONS
- REMOTE THERMOSTAT
wall plenum
RAVWP6 – Up to 6 in wall thickness
RAVWP8 – Up to 8 in wall thickness
RAVWP12 – Up to 12 in wall thickness
RAVWP15 – Up to 15 in wall thickness
- Wall plenum dimensions are 19-3/4 in × 32 in
- They come in a warm gray beige color
- Wall cutout dimensions are 20 in × 32-1/4 in
ARCHITECTURAL LOUVER
RAVAL1
ACCESS PANEL WITH RETURN AIR GRILLE
RAVRG1
RETURN AIR GRILLE
RAVRG2
Power connection kits are required on all GE Zoneline chassis. The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring.
230/208-VOLT UNITS
These units may be plugged into a receptacle using a line power cord kit or hard-wired. If the unit is to be permanently connected, a permanent connection kit would be used. Some installations utilize sub-bases for support of the unit and to hide the electrical connection.
POWER CORD KITS
RAK3152 (15 Amp) – NEMA6-15R
RAK3202 (20 Amp) – NEMA6-30R
RAK3302 (30 Amp) – NEMA6-30R
DIRECT CONNECT KITS
RAK4157 (15 Amp)
RAK4207 (20 Amp)
RAK4307 (30 Amp)
265-VOLT UNITS
265-volt units are provided with a junction box and require direct connection. 265-volt cord set units must be installed in compliance with National Electrical Code®.
DIRECT CONNECT KIT
To be used with a sub-base or connection to building whiring.
RAK5157 (15 Amp)
RAK5207 (20 Amp)
RAK5307 (30 Amp)
All Zoneline units are compatible with GE Appliances' wall-mounted remote thermostats. We offer both digital and programmable wired thermostats.
8500 electric resistance heat series
-
COOLING WITH ELECTRIC HEAT DIGITAL THERMOSTAT
RAK164D1 -
COOLING WITH ELECTRIC HEAT PROGRAMMABLE THERMOSTAT
RAK164P1
8500 HEAT PUMP SERIES
-
HEAT PUMP DIGITAL THERMOSTAT
RAK148D1 -
HEAT PUMP PROGRAMMABLE THERMOSTAT
RAK148P1