ZONELINE BUYING TIPS

ACCESSORY GUIDE FOR YOUR GE ZONELINE® PTAC

ACCESSORY GUIDE FOR YOUR GE ZONLINE PTAC

Zoneline packaged terminal air conditioner units are designed with universal components and offer great installation flexibility, whether in new construction, renovation or for replacement of old PTAC units.

ESSENTIAL ACCESSORIES

GE Zonelines require a set of essential accessories for proper operation. Once you have selected your type of unit (resistance heat or heat pump) and the size of unit needed, next you’ll need to consider the following:

For new properties, be sure to get a matching wall case with your GE Zoneline. For replacements, GE Zoneline fits in the standard 42 in × 16 in sleeve dimensions.

HEAVY GAUGE STEEL WALL CASE

RAB71B

  • Heavy gauge galvanized steel, with insulation
  • 42 in (A) × 13 3/4 in (B) × 16 in (C)
  • Also available in 16 in, 24 in, 28 in and 31 in depths
WALL OPENING DIMENSIONS
  • Add 1/4 in to A and C dimensions for all cutout size
  • 16 1/4 in min (height) × 42 1/4 in min (width)
FIBERGLASS WALL CASE

RAB77B

  • Molded SMC fiberglass-reinforced polyester compound
  • 42 in (A) × 13 7/8 in (B) × 16 1/4 in (C)
WALL OPENING DIMENSIONS
  • Add 1/4 in to A and C dimensions for all cutout size
  • 16 1/2 in min (height) × 42 3/8 in min (width)

We offer three styles of exterior grilles to fit your building façade. The exterior air flow requirements have changed over the years. If reusing an existing grille, make sure that the air flow pattern is compatible with the new chassis. This may include removing existing air deflectors off the grille and installing the RAK40 air deflectors on the chassis.

ARCHITECTURAL GRILLE

RAG67 – Aluminum

COLOR MOLDED GRILLES

RAG61 – Beige

RAG62 – Maple

RAG63 Dark Brown

STAMPED GRILLE

RAG60 – Aluminum

Power connection kits are required on all GE Zoneline chassis. The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring.

230/208-VOLT UNITS

These units may be plugged into a receptacle using a line power cord kit or hard-wired. If the unit is to be permanently connected, a permanent connection kit would be used. Some installations utilize sub-bases for support of the unit and to hide the electrical connection.

POWER CORD KITS

RAK315P (15 AMP) – NEMA6-15R

RAK320P (20 AMP) – NEMA6-20R

RAK330P (30 AMP) – NEMA6-30R

DIRECT CONNECT KITS

RAK315D (15 AMP)

RAK320D (20 AMP)

RAK330D (30 AMP)

SUB-BASES

230/208-volt sub-bases include the appropriate short power cord to connect to the receptacle inside the sub-base. A junction box kit is required to complete the direct connect installation.

RAK204D15C (15 Amp)

RAK204D20C (20 Amp)

RAK204D30C (30 Amp)

265-VOLT UNITS

265-volt units are provided with a junction box and require direct connection. 265-volt cord set units must be installed in compliance with National Electrical Code®.

POWER CORD KITS

To be used with a sub-base.

RAK515P (15 AMP) – NEMA7-15R

RAK520P (20 AMP) – NEMA7-20R

RAK530P (30 AMP) – NEMA7-30R

DIRECT CONNECT KITS

To be used with a sub-base or connection to building wiring. Direct connect kits include a power cord.

RAK515D (15 Amp)

RAK520D (20 Amp)

RAK530D (30 Amp)

SUB-BASES

Sub-bases do not include a power cord and junction box. Order a sub-base and the appropriate power cord or direct connect kit separately.

RAK204E15 (15 AMP)

RAK204E20 (20 AMP)

RAK204E30 (30 AMP)

OTHER ACCESSORIES

The 4500 and 6500 series can be used to heat or cool more than one room. A special adapter mounts on the wall case and a transition piece directs the air from the unit into added ductwork that distributes the air to the main room and the attached room.

DUCT ADAPTER

RAK6053

DUCT EXTENSION

RAK601B

DUCT EXTENSION

RAK602B

All Zoneline units are compatible with GE Appliances wall-mounted remote thermostats. We offer both digital and programmable wired thermostats.

4500 ELECTRIC RESISTANCE HEAT SERIES
  • COOLING WITH ELECTRIC HEAT DIGITAL THERMOSTAT

    RAK164D2
  • COOLING WITH ELECTRIC HEAT PROGRAMMABLE THERMOSTAT

    RAK164P2
  • DIGITAL TWO FAN SPEED THERMOSTAT FOR ELECTRIC RESISTANCE

    RAK164F2
6500 HEAT PUMP SERIES
  • HEAT PUMP DIGITAL THERMOSTAT

    RAK148D2
  • HEAT PUMP PROGRAMMABLE THERMOSTAT

    RAK148P2
  • DIGITAL TWO FAN SPEED THERMOSTAT FOR HEAT PUMP

    RAK148F2

ZONELINE BUYING TIPS

ACCESSORY GUIDE FOR YOUR GE ZONELINE VERTICAL AIR CONDITIONER

ACCESSORY GUIDE FOR YOUR GE ZONELINE VERTICAL AIR CONDITIONER

The GE Zoneline Vertical Air Conditioner is approximately 24 in × 24 in and has a top air discharge that is ducted into a single room or multiple rooms. Because the new Zoneline Vertical is installed in a closet, it provides a more home-like appearance to the room as well as quieter operation.

ESSENTIAL ACCESSORIES

GE Zonelines require a set of essential accessories for proper operation. Once you have selected your type of unit (resistance heat or heat pump) and the size of unit needed, next you’ll need to consider the following:

wall plenum

RAVWP6 – Up to 6 in wall thickness

RAVWP8 – Up to 8 in wall thickness

RAVWP12 – Up to 12 in wall thickness

RAVWP15 – Up to 15 in wall thickness

  • Wall plenum dimensions are 19-3/4 in × 32 in
  • They come in a warm gray beige color
  • Wall cutout dimensions are 20 in × 32-1/4 in

ARCHITECTURAL LOUVER

RAVAL1

ACCESS PANEL WITH RETURN AIR GRILLE

RAVRG1

RETURN AIR GRILLE

RAVRG2

Power connection kits are required on all GE Zoneline chassis. The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring.

230/208-VOLT UNITS

These units may be plugged into a receptacle using a line power cord kit or hard-wired. If the unit is to be permanently connected, a permanent connection kit would be used. Some installations utilize sub-bases for support of the unit and to hide the electrical connection.

POWER CORD KITS

RAK3152 (15 Amp) – NEMA6-15R

RAK3202 (20 Amp) – NEMA6-30R

RAK3302 (30 Amp) – NEMA6-30R

DIRECT CONNECT KITS

RAK4157 (15 Amp)

RAK4207 (20 Amp)

RAK4307 (30 Amp)

265-VOLT UNITS

265-volt units are provided with a junction box and require direct connection. 265-volt cord set units must be installed in compliance with National Electrical Code®.

DIRECT CONNECT KIT

To be used with a sub-base or connection to building whiring.

RAK5157 (15 Amp)

RAK5207 (20 Amp)

RAK5307 (30 Amp)

All Zoneline units are compatible with GE Appliances' wall-mounted remote thermostats. We offer both digital and programmable wired thermostats.

8500 electric resistance heat series
  • COOLING WITH ELECTRIC HEAT DIGITAL THERMOSTAT

    RAK164D1
  • COOLING WITH ELECTRIC HEAT PROGRAMMABLE THERMOSTAT

    RAK164P1
8500 HEAT PUMP SERIES
  • HEAT PUMP DIGITAL THERMOSTAT

    RAK148D1
  • HEAT PUMP PROGRAMMABLE THERMOSTAT

    RAK148P1